Blue Raid Status


Mon Nov 20 18:05:01 EST 2017


-- Controller information --
-- ID | H/W Model                  | RAM    | Temp | BBU    | Firmware     
c0    | LSI MegaRAID SAS 9260CV-8i | 512MB  | N/A  | Absent | FW: 12.12.0-0139 

-- Array information --
-- ID | Type   |    Size |  Strpsz |   Flags | DskCache |   Status |  OS Path | CacheCade             |InProgress   
c0u0  | RAID-1 |    931G |   64 KB |   RA,WB |  Enabled |  Optimal | /dev/sda | None                  |Check Consistency        : Completed 68%, Taken 62 min. 
c0u1  | RAID-6 |  10913G |   64 KB |   RA,WB |  Enabled |  Optimal | /dev/sdb | Type : Read and Write |Check Consistency        : Completed 9%, Taken 62 min. 
c0u2  | RAID-0 |    232G |         | ADRA,WB |      N/A |  Optimal |        2 | Associated : c0u1     |None         

-- Disk information --
-- ID  | Type | Drive Model                                        | Size     | Status          | Speed    | Temp | Slot ID  | LSI Device ID
c0u0p0 | HDD  | Z4YE0JBSST1000DM003-1ER162 CC46                    | 931.0 GB | Online, Spun Up | 6.0Gb/s  | 24C  | [252:0]  | 11      
c0u0p1 | HDD  | Z4YBCB4LST1000DM003-1ER162 CC46                    | 931.0 GB | Online, Spun Up | 6.0Gb/s  | 23C  | [252:1]  | 10      
c0u1p0 | HDD  | WOL240343752WL6000GSA6457 82.00A82                 | 5.456 TB | Online, Spun Up | 6.0Gb/s  | 25C  | [252:2]  | 14      
c0u1p1 | HDD  | WOL240343748WL6000GSA6457 82.00A82                 | 5.456 TB | Online, Spun Up | 6.0Gb/s  | 27C  | [252:3]  | 15      
c0u1p2 | HDD  | WD-WXB1HB4H5Z4ZWDC WD60EZRZ-00GZ5B1 80.00A80       | 5.457 TB | Online, Spun Up | 6.0Gb/s  | 26C  | [252:4]  | 16      
c0u1p3 | HDD  | WOL240345853WL6000GSA6457 82.00A82                 | 5.457 TB | Online, Spun Up | 6.0Gb/s  | 26C  | [252:5]  | 17      
c0u2p0 | SSD  | S2R5NB0HC08829A Samsung SSD 850 EVO 250GB EMT02B6Q | 232.3 Gb | Online, Spun Up | 6.0Gb/s  | N/A  | [252:6]  | 9       


                                     

Adapter 0 -- Virtual Drive Information:
Virtual Drive: 0 (Target Id: 0)
Name                :
RAID Level          : Primary-1, Secondary-0, RAID Level Qualifier-0
Size                : 931.0 GB
Sector Size         : 512
Is VD emulated      : Yes
Mirror Data         : 931.0 GB
State               : Optimal
Strip Size          : 64 KB
Number Of Drives    : 2
Span Depth          : 1
Default Cache Policy: WriteBack, ReadAhead, Cached, Write Cache OK if Bad BBU
Current Cache Policy: WriteBack, ReadAhead, Cached, Write Cache OK if Bad BBU
Default Access Policy: Read/Write
Current Access Policy: Read/Write
Disk Cache Policy   : Enabled
Ongoing Progresses:
  Check Consistency        : Completed 68%, Taken 62 min.
Encryption Type     : None
Is VD Cached: No


Virtual Drive: 1 (Target Id: 1)
Name                :
RAID Level          : Primary-6, Secondary-0, RAID Level Qualifier-3
Size                : 10.913 TB
Sector Size         : 512
Is VD emulated      : Yes
Parity Size         : 10.913 TB
State               : Optimal
Strip Size          : 64 KB
Number Of Drives    : 4
Span Depth          : 1
Default Cache Policy: WriteBack, ReadAhead, Cached, Write Cache OK if Bad BBU
Current Cache Policy: WriteBack, ReadAhead, Cached, Write Cache OK if Bad BBU
Default Access Policy: Read/Write
Current Access Policy: Read/Write
Disk Cache Policy   : Enabled
Ongoing Progresses:
  Check Consistency        : Completed 9%, Taken 62 min.
Encryption Type     : None
Is VD Cached: Yes
Cache Cade Type : Read and Write


CacheCade Virtual Drive: 2 (Target Id: 2)
Virtual Drive Type    : CacheCade 
Name          : 
RAID Level        : Primary-0, Secondary-0
State             : Optimal
Size          : 232.375 GB
Target Id of the Associated LDs : 1
Default Cache Policy  : WriteBack, ReadAdaptive, Direct, Write Cache OK if Bad BBU
Current Cache Policy  : WriteBack, ReadAdaptive, Direct, Write Cache OK if Bad BBU



Exit Code: 0x00
###############################################

                                     
Adapter 0: Patrol Read Information:

Patrol Read Mode: Auto
Patrol Read Execution Delay: 168 hours
Number of iterations completed: 61 
Next start time: 11/23/2017, 06:00:00
Current State: Stopped
Patrol Read on SSD Devices: Disabled

Exit Code: 0x00
###############################################

                                     
Check Consistency on VD #0 (target id #0) Completed 68% in 62 Minutes.
Check Consistency on VD #1 (target id #1) Completed 9% in 62 Minutes.
Check Consistency on VD #2 is not in progress.

Exit Code: 0x00

This page will reload every 30 seconds.