Blue Raid Status


Sun Jul 22 20:00:01 EDT 2018


-- Controller information --
-- ID | H/W Model                  | RAM    | Temp | BBU    | Firmware     
c0    | LSI MegaRAID SAS 9260CV-8i | 512MB  | N/A  | Absent | FW: 12.12.0-0139 

-- Array information --
-- ID | Type   |    Size |  Strpsz |   Flags | DskCache |   Status |  OS Path | CacheCade         |InProgress   
c0u0  | RAID-1 |    931G |   64 KB |   RA,WB |  Enabled |  Optimal | /dev/sda | None              |None         
c0u1  | RAID-6 |  10913G |   64 KB |   RA,WB |  Enabled |  Optimal | /dev/sdb | Type : Read Only  |None         
c0u2  | RAID-1 |    232G |         | ADRA,WT |      N/A |  Optimal |        2 | Associated : c0u1 |None         

-- Disk information --
-- ID  | Type | Drive Model                                        | Size     | Status          | Speed    | Temp | Slot ID  | LSI Device ID
c0u0p0 | HDD  | S1D254J5ST1000DM003-9YN162 CC4B                    | 931.0 GB | Online, Spun Up | 6.0Gb/s  | 32C  | [252:0]  | 11      
c0u0p1 | HDD  | Z4YBCB4LST1000DM003-1ER162 CC46                    | 931.0 GB | Online, Spun Up | 6.0Gb/s  | 28C  | [252:1]  | 10      
c0u1p0 | HDD  | WOL240343752WL6000GSA6457 82.00A82                 | 5.456 TB | Online, Spun Up | 6.0Gb/s  | 31C  | [252:2]  | 14      
c0u1p1 | HDD  | WOL240343748WL6000GSA6457 82.00A82                 | 5.456 TB | Online, Spun Up | 6.0Gb/s  | 32C  | [252:3]  | 15      
c0u1p2 | HDD  | K1H87PVD HGST HDN726060ALE614 APGNW7JH             | 5.457 TB | Online, Spun Up | 6.0Gb/s  | 35C  | [252:4]  | 16      
c0u1p3 | HDD  | WOL240345853WL6000GSA6457 82.00A82                 | 5.457 TB | Online, Spun Up | 6.0Gb/s  | 32C  | [252:5]  | 17      
c0u2p0 | SSD  | S2R5NB0HC08829A Samsung SSD 850 EVO 250GB EMT02B6Q | 232.3 Gb | Online, Spun Up | 6.0Gb/s  | N/A  | [252:6]  | 9       
c0u2p1 | SSD  | S2R5NB0HC10508F Samsung SSD 850 EVO 250GB EMT02B6Q | 232.3 Gb | Online, Spun Up | 6.0Gb/s  | N/A  | [252:7]  | 18      


                                     

Adapter 0 -- Virtual Drive Information:
Virtual Drive: 0 (Target Id: 0)
Name                :
RAID Level          : Primary-1, Secondary-0, RAID Level Qualifier-0
Size                : 931.0 GB
Sector Size         : 512
Is VD emulated      : Yes
Mirror Data         : 931.0 GB
State               : Optimal
Strip Size          : 64 KB
Number Of Drives    : 2
Span Depth          : 1
Default Cache Policy: WriteBack, ReadAhead, Cached, Write Cache OK if Bad BBU
Current Cache Policy: WriteBack, ReadAhead, Cached, Write Cache OK if Bad BBU
Default Access Policy: Read/Write
Current Access Policy: Read/Write
Disk Cache Policy   : Enabled
Encryption Type     : None
Is VD Cached: No


Virtual Drive: 1 (Target Id: 1)
Name                :
RAID Level          : Primary-6, Secondary-0, RAID Level Qualifier-3
Size                : 10.913 TB
Sector Size         : 512
Is VD emulated      : Yes
Parity Size         : 10.913 TB
State               : Optimal
Strip Size          : 64 KB
Number Of Drives    : 4
Span Depth          : 1
Default Cache Policy: WriteBack, ReadAhead, Cached, Write Cache OK if Bad BBU
Current Cache Policy: WriteBack, ReadAhead, Cached, Write Cache OK if Bad BBU
Default Access Policy: Read/Write
Current Access Policy: Read/Write
Disk Cache Policy   : Enabled
Encryption Type     : None
Is VD Cached: Yes
Cache Cade Type : Read Only


CacheCade Virtual Drive: 2 (Target Id: 2)
Virtual Drive Type    : CacheCade 
Name          : 
RAID Level        : Primary-1, Secondary-0
State             : Optimal
Size          : 232.375 GB
Target Id of the Associated LDs : 1
Default Cache Policy  : WriteThrough, ReadAdaptive, Direct, Write Cache OK if Bad BBU
Current Cache Policy  : WriteThrough, ReadAdaptive, Direct, Write Cache OK if Bad BBU



Exit Code: 0x00
###############################################

                                     
Adapter 0: Patrol Read Information:

Patrol Read Mode: Auto
Patrol Read Execution Delay: 168 hours
Number of iterations completed: 95 
Next start time: 07/24/2018, 12:00:00
Current State: Stopped
Patrol Read on SSD Devices: Disabled

Exit Code: 0x00
###############################################

                                     
Check Consistency on VD #0 is not in progress.
Check Consistency on VD #1 is not in progress.
Check Consistency on VD #2 is not in progress.

Exit Code: 0x00
###############################################
 
Filesystem                   Size  Used Avail Use% Mounted on
udev                          16G   12K   16G   1% /dev
tmpfs                        3.1G   10M  3.1G   1% /run
/dev/sda1                    886G  137G  705G  17% /
none                         4.0K     0  4.0K   0% /sys/fs/cgroup
none                         5.0M  4.0K  5.0M   1% /run/lock
none                          16G     0   16G   0% /run/shm
none                         100M     0  100M   0% /run/user
/dev/sdb1                     11T  7.6T  2.8T  74% /media/primary
/dev/mapper/Primary-Primary   14T   11T  2.5T  82% /media/backup
###############################################
 
Filesystem                    1K-blocks        Used  Available Use% Mounted on
udev                           15913208          12   15913196   1% /dev
tmpfs                           3185340       10156    3175184   1% /run
/dev/sda1                     928839104   143122340  738511388  17% /
none                                  4           0          4   0% /sys/fs/cgroup
none                               5120           4       5116   1% /run/lock
none                           15926696           0   15926696   0% /run/shm
none                             102400           0     102400   0% /run/user
/dev/sdb1                   11626220424  8119653944 2920615760  74% /media/primary
/dev/mapper/Primary-Primary 14535704248 11278636056 2622179900  82% /media/backup

This page will reload every 30 seconds.